PRODUCTS

Calorimeter

Ultraflow 54
ULTRAFLOW 54 is a flow meter based on the ultrasonic principle.
It is mainly used as a volume flow sensor with Multical series.

 

 

 

 

 

 

 

 

 

 

Nom.flow qp
[m³/h]
Nom.diameter
[mm]
Meter factor
[imp/l]
Dynamic range
qi:qp
qs : qp flow@125Hz
[m³/h]
△p@qp
[bar]
Min.cutoff
[l/h]
0.6 DN15&DN20 300 1 : 100 2:1 1.5 0.04 2
1.5 DN15&DN20 100 1 : 100 2:1 4.5 0.22 3
2.5 DN20 60 1 : 100 2:1 7.5 0.03 5
3.5 DN25 50 1 : 100 2:1 9 0.07 7
6 DN25& DN32 25 1 : 100 2:1 18 0.2 12
10 DN40 15 1 : 100 2:1 30 0.06 20
15 DN50 10 1 : 100 2:1 45 0.14 30
25 DN65 6 1 : 100 2:1 75 0.06 50
40 DN80 5 1 : 100 2:1 90 0.05 80
60 DN100 2.5 1 : 100 2:1 180 0.03 120
100 DN100&DN125 1.5 1 : 100 2:1 300 0.07 200